Renetech Sdn Bhd
28-G & 28-1, Jalan Suria Puchong 4,
Pusat Perniagaan Suria Puchong,
47110 Puchong,
Selangor, Malaysia.
+6012-234 0081

Steam Sterilizer (Laboratory Use, with Drying Process) (SM311)

Previous 7 / 10 Next

Steam Sterilizer (Laboratory Use, with Drying Process) (SM311) SM Series Steam Sterilizer Sterilizer


Fully automatic sterilization from start to the end with high pressure steam sterilization followed by ''Drying'' process
 
Features of Steam Sterilizer (Laboratory Use, with Drying Process) (SM311)
  • Automatic operation from sterilization to drying process can be easily set by the interactive key input system.
  • Quick sample drying function makes samples ready to use right after sterilization.
  • Drying temperature can be set depending on the application within the range from 150 to 180¡æ.
  • The water level in drain bottle can be easily checked with the level indicator on the front panel.
Specifications
Item Code 00
Model SM311
System Automatic high-pressure steam sterilization
Operating temp. range (Sterilization) 105¡«128¡æ
Operating temp. range (Drying) 150¡«180¡æ
Max. pressure capacity 0.2MPa
Safety device Self-diagnostic functions(Detection sensor error, SSR short circuit, Heater disconnection, Main relay error), Safety valve, ELB, Drain bottle switch
Accessories Stainless steel mesh basket (262dia. x 204Dmm) x 2 pcs., Drain board, Chemical indicator strip, Drain bottle, Condensation collection container with magnetic bracket, each 1 pc.
Interior Stainless steel
Temp. Controller PID control by microprocessor
Temp. Display Digital display by green LED and setting by UP/DOWN key
Timer/Resolution 1 min. ¡«99hrs. and 59min./100¡«999hrs./1min. or 1hr.
Internal dimensions£¨φ×H mm£© φ300×455mm
External dimensions£¨W×D×H mm£© 440×530×968mm
Remarks(dimensions) 32L
Power Source 220V 9.5A
00
Weight 80kg
 
Maintenance and warranty
  1. Yamato autoclaves are for laboratory use only. They cannot be operated for medical use.
  2. The pressure vessel conforms to the safety standards in Japan. Any clarification or modification works to meet the local safety standards in each country shall be out of the manufacturer’s scope.
  3. Conditions: temperature and humidity: 23 deg.C+/-5 deg.C, 65%RH+/-20% (no load)
  4. External dimensions do not include protrusions.